Aga Ranges GCB Manual Do Utilizador

Página de 8
3
NATURAL G20
MAXIMUM HEAT INPUT
5kW
5.8kW
Thermostat Bypass
100 or 120
120 or 140
Main Burner Injector
285
330
Pilot Injector
N35
N35
Inlet Pressure G20
20mbar
20mbar
PROPANE G31
MAXIMUM HEAT INPUT
5kW (357g/h) 5.8kW (414g/h)
Thermostat Bypass
60 or 80
80 or 100
Main Burner Injector
180
200
Pilot Injector
L23
L23
Inlet Pressure
37mbar
37mbar
Burner Pressure
28mbar
32mbar
Models GE and GEB Balanced flue
GE
GEB
A
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
S
T
U
V
mm 1487 889 851 679 41 1330 756 1125 39
3
698 632 591 51
67
R
116 770 484 328 828
For Natural Gas the gas valve outlet pressure is non-adjustable, BUT for reference purposes only. A pressure
drop of 1-2mbar can be observed between inlet and outlet pressures on a cold appliance.
V = VENT PIPE
S = FLUE PIPE