Bunn ULTRA-2 PAFA Manual Do Utilizador

Página de 4
8. Wash components in a mild 
solution of dish detergent using 
a  bristle  brush.  Rinse  and  dry 
each  item  thoroughly  before 
reassembling.
NOTE: Parts must be thoroughly 
dry before adding powder to the 
hopper.
7. Slip the O-ring off the Whip-
per  Chamber  Receptacle  and 
remove the shaft seal.
4. Twist the Whipper Chamber 
clockwise  and  pull  it  off  the 
Whipper Chamber Receptacle.
5. Pull the Frother off the Motor 
Shaft. Notice the flat keyway on 
the shaft and the matching key-
way inside the Frother. It is im-
portant that these two keyways 
are lined up when reassembling.
6. Twist Whipper Chamber Re-
ceptacle clockwise and pull it off 
the Motor Shaft. Wipe down all 
inside surfaces.
USE & CARE INSTRUCTIONS for ULTRA-2 COLD DRINK DISPENSER WITH PAF DISPENSER
NOTICE - This guide is for quick reference only and is not intended to replace the information in the Operation Manual! 
DISASSEMBLY & CLEANING
EMPTY ALL PRODUCT FROM THE ULTRA HOPPERS INTO A BUCKET OR CONTAINER BEFORE PROCEEDING!
1.  Open  the  Cabinet  Door  and 
allow the support arms to lock 
in  place.  Door  must  remain 
open during the entire cleaning 
procedure.
3. Pull the Mixing Chamber out 
of the Whipper Chamber.
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601    FAX: (217) 529-6644
43553.0000A  07/10   ©2010  Bunn-O-Matic Corporation
ULTRA-2 PAF
ULTRA-2 PAFA
(Page 1 of 4, Continued)
2.  Place  the  power  switch  in 
the OFF position. Slide the gate 
shut on the powder hopper and 
remove  the  hopper.  Wipe  the 
hopper  tray  clean  of  powder 
residue.