General Information
 The cleaning of beer lines with the new inte-
gral flow reversal feature incorporated into the 
Perlick Beer Pump gives the line cleaner  
numerous configurations for line cleaning. 
Although the Perlick Beer Pump can be used 
as an in-line pump for moving the solution from 
the coupler to the faucet due to its capability of 
working with negative lift, the following is the 
recommended method for cleaning beer lines 
with the Perlick Beer Pump with integral flow 
reversal installed.
Cleaning Beer Lines using Smart Couplers
Disconnect Smart Coupler from beer connector  
 
lines and soak Smart Couplers in cleaning  
 
solution.
 Couple the two beer connectors together using 
Perlick’s double male adapter part # 186 with 
beer washers.
   Determine which sets of lines will be cleaned  
  together and rotate the Dispense/Reverse Flow  
  handle to the Reverse Flow position on the line  
  which fluid will be circulated from the faucet, to  
  the tap.
Remove the faucet from the line to which the  
 
Beer Line Cleaner pump will be connected. Soak  
 
faucets and brush clean before reinstalling. 
 Connect Beer Line Cleaner pump to the shank.
 Follow standard beer line cleaning procedures. 
Perlick recommends that the lines first be flushed 
with clean warm water (Water temperature not 
 
to exceed 100 degrees). Mix line-cleaning  
 
solution per manufacturerís directions.  
 
Circulate the solution thoroughly (Time for  
 
circulation dependent on length of the system  
 
and pump capabilities). Rinse the lines using  
 
clean cold water (Ensure all line cleaning solution  
 
has been removed from the lines to prevent  
 
hazardous results).
 Disconnect line-cleaning pump and reinstall beer 
faucets.
Reconnect couplers to beer connector lines and  
 
return Beer Pump Dispense/ Reverse Flow valve  
 
to the dispense position.
 Reconnect couplers to keg and open dispensing 
head faucets until clear beer flows.
Winterizing Systems with Beer Pumps
 When a beer system with beer pumps will be 
shut down for an extended period, clean the 
system thoroughly. After completing the rins-
ing step, prepare a mixture of 50% food grade 
Glycerine and 50% water. Load the lines with 
this mixture and make sure both ends of the 
system are closed. Glycerine/water mixture 
should remain in the lines for the duration of  
the shutdown period.
Replacement Parts
44................... Air valve
40115 ............. Regulator body
40129............. Regulator body
43553A .......... Regulator repair kit
63706............. Flow reversal valve
63707............. Elbow, flow reversal, 2/bag
63708............. Fitting, tee, gas, barbed 
1
/
4
” with 
 
 
check valve
63709 ............. Fitting, elbow, gas, barbed 
1
/
4
” with 
 
 
check valve
43817............. Beer pump, Flo-Jet, w/CO
2
 elbow 
 
 
& tee
7
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Cleaning Instructions
Form No. Z2149A
Rev. 10.11.06