SPECIAL COMPONENTS TEST AND ADJUSTMENTS 
 
 
1)  WATER INLET VALVE (SOLENOID) TEST 
(
Located inside bottom cabin
)
 
  
Turn power off from touchpad. If the water level rises inside the tank, and shoots out 
of the overflow, the Water Inlet Valve is leaking.  Disconnect wires from the Water Inlet 
Valve coil and connect a 2 wire line cord to the terminals. Plug it into a 115V outlet.  If 
water flows in and stops when you pull it out, the Valve is working fine. Repeat this 
test a few times.  The problem may be in the Probe.  If the water does not flow in 
when the cord is plugged into an electrical outlet, the Solenoid coil may be damaged, 
opened or the valve may have an obstruction preventing the water from flowing in.  
Clean or replace it. 
    
 
A Check Valve is installed to prevent backflow.   
 
To check proper function of Check Valve, disconnect water line from the Check 
Valve, check for dripping from the disconnected end of the Check Valve.    
       If it leaks replace it.  
 
    Water inlet Valve max. flow rate is 
1.3 gal/min
.  
 
2)  WATER LEVEL PROBE TEST (
Located on tank top, inside top cabin
)
 
 
 
If there is a lack of water, you will get an error message on the LCD window.  
        Check the probe as follows: 
 
Turn on the power from touchpad and water supply.  Check inside the tank to make 
sure the water is not touching the Probe.  Pull the wire and terminal out of the 
Probe rod.  If water starts flowing into the tank, the Probe may be grounded, due to 
excessive liming.  Check with Ohm meter.  Clean or replace. 
 
3)   POWER SAFETY RELAY TEST (
Located inside top cabin
) 
        Turn  power switch on from touchpad.  Measure Voltage across Input to Coil, 
        between terminals12.  Should read approx. 9V to 10V D.C. 
  Measure Voltage across Input, between terminals “COM” to Ground.  Should read 120V. 
  Measure Voltage across Output, between terminals “NO” to Ground.  Should read 120V. 
 
4)   HEATER SAFETY RELAY TEST (240V UNITS ONLY) (
Located inside top cabin
)   
        Make sure power switch in back of unit is on (toggle up). 
       
       
Turn power switch on (energize) from touchpad. Measure Input Voltage across coil,  
        between terminals 0 & 1.  Should read 120V. 
   
      Measure Output Voltage across Heater Element.  Should read 220 V.  If there is no 
Voltage across the Heating Element, measure Output Voltage between terminals 4 & 8. 
 
Turn power switch  off from touchpad.  The Voltage should be a constant 220V  even when not energized. 
 
Turn power switch on) from touchpad.  Measure Voltage across terminals 2 & 6.  Should read 220V
If 120V was applied to relay coil and it does not energize, replace relay.