When installing a quick disconnect you must also install a means for 
limiting the movement of the fryer.  This device will prevent the gas line or quick 
disconnect from being strained.  The restraining device should be attached to the 
cutout on the back panel.  See illustration for location. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Š 
In Australia, use only the caster supplied by the manufacturer for the fryer 
device.  The fryer must be installed using a hose assembly restraining device to 
limit the movement of the appliance in accordance with AS1869. 
 
Š 
The fryer must be installed with a connector (not supplied by Vulcan)  
complying with the above codes. 
 
Š 
The fryer must be installed with restraining means to guard against  
transmission of strain to the connector.  See illustration. 
 
 
Š 
The fryer must be installed with the casters provided. 
 
 
Š 
If the restraint is ever to be disconnected, first turn the gas supply off. 
 
 
LEVELING THE FRYER 
 
Check the level of the fryer by placing a level on top of the fryer after gas connections have 
been made. 
 
Ensure that the fryer is level front-to-back and side-to-side in the final installed position. 
 
If using casters, lock the wheels after unit is level.