30” Under-the-counter-Units
A single oven installed under the 
counter allows for the installation 
of most Thermador Gas or Electric 
non-Cook’n’Vent® Model Cook-
tops. Downdraft units cannot be 
installed in this configuration; 
Thermador overhead ventilation is 
recommended.
Some TMH cooktops require addi-
tional clearances to combustible 
walls.
A Thermador cooktop should be 
installed on the same center line 
as the under-the-counter single 
oven. Follow the installation in-
structions provided with cooktop 
for installation of cooktops. 3 3/4” 
inches (95mm) minimum is re-
quired from the top of the counter-
top to the top of the cutout opening 
for under-counter installation with 
Thermador cooktops. If the type of 
cabinet or countertop thickness 
does not provide for this minimum 
space, the cabinet base may have 
to be lowered, into the toe space, 
to provide the necessary space 
above the oven. However, a 4” 
minimum distance between the 
floor and the oven bottom must re-
main.