Hoshizaki DCM-500BAH-OS Manual Do Utilizador

Página de 69
34
E. Performance Data
1. DCM-500BAH(-OS)
Note:
1. The data without *marks should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior 
notice.
APPROXIMATE
Ambient
Water Temp.  (°F)
ICE PRODUCTION
Temp.  (°F)
PER 24 HR.
70
*535
(243)
510
(231)
485
(220)
80
461
(209)
438
(199)
416
(189)
90
396
(179)
*385
(175)
358
(162)
lbs./day  ( kg/day)
100
340
(154)
323
(147)
*304
(138)
APPROXIMATE ELECTRIC
70
*985
--
995
--
1005
--
CONSUMPTION
80
1015
--
1025
--
1035
--
90
1045
--
*1055
--
1056
--
watts
100
1058
--
1059
--
*1060
--
APPROXIMATE WATER
70
*64
(243)
61
(231)
58
(220)
CONSUMPTION PER 24 HR.
80
55
(209)
53
(199)
50
(189)
90
48
(179)
*46
(175)
43
(162)
gal. / day  (l/day)
100
41
(154)
39
(147)
*37
(138)
EVAPORATOR OUTLET TEMP.
70
*23
(-5)
23
(-5)
23
(-5)
°F  (°C)
80
23
(-5)
26
(-4)
26
(-4)
90
26
(-4)
*26
(-4)
28
(-3)
100
28
(-3)
28
(-3)
*28
(-3)
HEAD PRESSURE
70
*230
(16.2)
230
(16.2)
230
(16.2)
80
264
(18.5)
264
(18.5)
264
(18.5)
90
297
(20.9)
*297
(20.9)
297
(20.9)
PSIG (kg/cm
2
G)
100
335
(23.5)
335
(23.5)
*335
(23.5)
SUCTION PRESSURE
70
*33
(2.3)
33
(2.3)
33
(2.3)
PSIG (kg/cm
2
G)
80
35
(2.5)
35
(2.5)
35
(2.5)
90
37
(2.6)
*37
(2.6)
37
(2.6)
100
43
(3.0)
43
(3.0)
*43
(3.0)
TOTAL HEAT OF REJECTION
6300 BTU/h  (AT 90°F /WT 70°F)
50
70
90