National Instruments 321645c-01 Manual Do Utilizador

Página de 554
Chapter 2
Function Reference — ICTR_Read
NI-DAQ FRM for PC Compatibles
2-248
©
 National Instruments Corporation
ICTR_Read
Format
status = ICTR_Read (deviceNumber, ctr, count)
Purpose
Reads the current contents of the selected counter without disturbing the counting process and 
returns the count.
Parameters
Input
Output
Parameter Discussion
ctr is the counter number.
Range:
0 through 2.
count returns the current count of the specified counter while the counter is counting down. 
count can be between zero and 65,535 when ctr is configured in binary mode (the default). 
count can be between zero and 9,999 if the last call to 
ICTR_Setup
 configured ctr in 
BCD counting mode.
Note
C Programmers—count is a pass-by-reference parameter.
Name
Type
Description
deviceNumber
i16
assigned by configuration utility
ctr
i16
counter number
Name
Type
Description
count
u16
current count