Moxa 8-Port Serial Device Server EU NPORT 5630-8-EU Manual Do Utilizador
Códigos do produto
NPORT 5630-8-EU
8-28
w w w. m o x a . c o m
i n f o @ m o x a . c o m
8
Serial Device Ser
vers
>
NPort® 5600 Rackmount Series
Serial-to-Ethernet Solutions
Dimensions
Physical Characteristics
Housing: SECC sheet metal (1 mm), providing IP30 protection
Weight:
NPort® 5610-8: 3340 g
NPort® 5610-8-48V: 3160 g
NPort® 5630-8: 3380 g
NPort® 5650-8: 3360 g
NPort® 5650-8-S-SC: 3380 g
NPort® 5650-8-M-SC: 3380 g
NPort® 5610-16: 3420 g
NPort® 5610-16-48V: 3260 g
NPort® 5630-16: 3400 g
NPort® 5650-16: 3460 g
NPort® 5650-16-S-SC: 3440 g
NPort® 5650-16-M-SC: 3440 g
Dimensions:
Without ears: 440 x 45 x 198 mm (17.32 x 1.77 x 7.80 in)
With ears: 480 x 45 x 198 mm (18.90 x 1.77 x 7.80 in)
Weight:
NPort® 5610-8: 3340 g
NPort® 5610-8-48V: 3160 g
NPort® 5630-8: 3380 g
NPort® 5650-8: 3360 g
NPort® 5650-8-S-SC: 3380 g
NPort® 5650-8-M-SC: 3380 g
NPort® 5610-16: 3420 g
NPort® 5610-16-48V: 3260 g
NPort® 5630-16: 3400 g
NPort® 5650-16: 3460 g
NPort® 5650-16-S-SC: 3440 g
NPort® 5650-16-M-SC: 3440 g
Dimensions:
Without ears: 440 x 45 x 198 mm (17.32 x 1.77 x 7.80 in)
With ears: 480 x 45 x 198 mm (18.90 x 1.77 x 7.80 in)
Environmental Limits
Operating Temperature: 0 to 55°C (32 to 131°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 75°C (-4 to 167°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -20 to 75°C (-4 to 167°F)
Power Requirements
Input Voltage:
NPort® 5610/5630/5650: 100 to 240 VAC, 47 to 63 hz
NPort® 5610-48V: ±48 VDC (20 to 72 VDC, -20 to -72 VDC)
Power Consumption:
NPort® 5610-8/16: 141 mA @ 100 VAC, 93 mA @ 240 VAC
NPort® 5630-8/16: 152 mA @ 100 VAC, 98 mA @ 240 VAC
NPort® 5610-8/16-48V: 135 mA @ 48 VDC
NPort® 5650-8/16: 158 mA @ 100 VAC, 102 mA @ 240 VAC
NPort® 5650-8/16-S-SC: 164 mA @ 100 VAC, 110 mA @ 240 VAC
NPort® 5650-8/16-M-SC: 174 mA @ 100 VAC, 113 mA @ 240 VAC
Power Line Protection: 4 KV burst (EN61000-4-4: EFT/B), 2 KV
surge (EN61000-4-5)
NPort® 5610/5630/5650: 100 to 240 VAC, 47 to 63 hz
NPort® 5610-48V: ±48 VDC (20 to 72 VDC, -20 to -72 VDC)
Power Consumption:
NPort® 5610-8/16: 141 mA @ 100 VAC, 93 mA @ 240 VAC
NPort® 5630-8/16: 152 mA @ 100 VAC, 98 mA @ 240 VAC
NPort® 5610-8/16-48V: 135 mA @ 48 VDC
NPort® 5650-8/16: 158 mA @ 100 VAC, 102 mA @ 240 VAC
NPort® 5650-8/16-S-SC: 164 mA @ 100 VAC, 110 mA @ 240 VAC
NPort® 5650-8/16-M-SC: 174 mA @ 100 VAC, 113 mA @ 240 VAC
Power Line Protection: 4 KV burst (EN61000-4-4: EFT/B), 2 KV
surge (EN61000-4-5)
Regulatory Approvals
EMC: CE (EN55022 Class A, EN55024), FCC Part 15 Subpart B
Class A
NPort® 5610 only: IEC61000-4-12
Safety: UL (UL60950-1), TÜV (EN60950-1)
Medical: EN60601-1-2 Class B, EN55011
Class A
NPort® 5610 only: IEC61000-4-12
Safety: UL (UL60950-1), TÜV (EN60950-1)
Medical: EN60601-1-2 Class B, EN55011
Reliability
Automatic Reboot Trigger: Built-in WDT (watchdog timer)
MTBF (meantime between failures):
NPort® 5610-8: 97294 hrs
NPort® 5610-16: 94928 hrs
NPort® 5610-8-48V: 96758
NPort® 5610-16-48V: 94417 hrs
NPort® 5630-8: 118405 hrs
NPort® 5630-16: 91483 hrs
NPort® 5650-8: 117584 hrs
NPort® 5650-16: 104767 hrs
NPort® 5650-S-SC-8: 116914 hrs
NPort® 5650-S-SC-16: 87528 hrs
NPort® 5650-M-SC-8: 116914 hrs
NPort® 5650-M-SC-16: 87528 hrs
MTBF (meantime between failures):
NPort® 5610-8: 97294 hrs
NPort® 5610-16: 94928 hrs
NPort® 5610-8-48V: 96758
NPort® 5610-16-48V: 94417 hrs
NPort® 5630-8: 118405 hrs
NPort® 5630-16: 91483 hrs
NPort® 5650-8: 117584 hrs
NPort® 5650-16: 104767 hrs
NPort® 5650-S-SC-8: 116914 hrs
NPort® 5650-S-SC-16: 87528 hrs
NPort® 5650-M-SC-8: 116914 hrs
NPort® 5650-M-SC-16: 87528 hrs
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
Details: See www.moxa.com/warranty
440 mm(17.3 in)
480 mm(19 in)
198
m
m
(7.8 in
)
45 mm (1.77 in
)
LA N
5610-16
Serial ports
AC POWER 100-240V,47-63Hz
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16