KitchenAid LI3Y7C Manual Do Utilizador

Página de 28
9
4. Run home power supply wiring through 
¹⁄₂" strain relief into 
terminal box.
5. Use UL listed wire connectors and connect white wires (B) 
together.
6. Use UL listed wire connectors and connect black wires (C) 
together.
7. Connect green (or bare) ground wire from home power supply 
to the 2 yellow-green ground wires (D) in terminal box using 
UL listed wire connectors.
8. Tighten strain relief screw.
9. Install terminal box cover.
10. Reconnect power.
Install Vent Covers
1. When using both upper and lower vent covers, push lower 
cover down onto hood and lift upper cover to ceiling and 
install with 2 - 2.9 x 6.5 mm screws.
NOTE: For vented installations, the upper vent cover may be 
reversed to hide slots.
Complete Installation
1. For non-vented (recirculating) installations only, install 
charcoal filters over grille on blower housing. See the “Range 
Hood Care” section.
2. Install metal filters. See the “Range Hood Care” section.
3. Check the operation of the range hood blower and light. See 
the “Range Hood Use” section.
NOTE: To get the most efficient use from your new range hood, 
read the “Range Hood Use” section.
A. UL listed wire connectors
B. White wires
C. Black wires
D. Green (or bare) wire connected to 
yellow-green wires
E. Home power supply
A
B
C
D
E
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.
A. Upper vent cover
B. Lower vent cover
C. 2.9 x 6.5 mm screws
D. Bracket
A
B
C
C
D