Installation Preparation
3
REQUIRED ACCESSORIES
This book provides step by step instructions to install
the Monogram ZV850 ceiling mounted hood for
recirculating
 operation.
• One of the following accessory kits is required for non-
vented ceiling mounted installations of model ZV850.
Choose the correct kit according to ceiling heights:
ZXR858
 – For 8 ft. ceiling height.
ZXR859
 – For 9 ft. ceiling height
ZXR8510
  – For 10 ft. ceiling height.
• Order the required accessory at the same time as the
vent hood and have on site before installation.
• Each kit includes decorative duct covers, a support
frame, air deflector and charcoal filters.
PRODUCT DIMENSIONS
The vent hood must be installed 24
″ min. and 30″ max.
above the cooking surface. 25-1/2
″ is recommended for
best performance and to ensure that the duct cover
meets the ceiling. The cooking surface should be at least
36
″ above the floor. Installation will be easier if the vent
hood is installed before the cooktop and countertop is
installed.
* 26-1/4” for 8 ft. Ceiling
Using ZXR858 Accessory
38-1/8” for 9 ft. Ceiling
Using ZXR859 Accessory
50-1/8” for 10 ft. Ceiling
Using ZXR8510 Accessory
* The distance between the cooking surface and the bottom of the
hood must be at least 24” and up to 30”. The 25-1/2” recommended
installation height, above the standard 36” countertop, will ensure
duct cover fit to the ceiling.
*25-1/2" Recommended
36" Reference
*Height 
to Ceiling
8-1/4"
35-3/8"
27-1/2"