NI PXI/PCI-5114 Specifications
16
ni.com
Environment
NI PXI-5114
Note 
To ensure that the NI PXI-5114 cools effectively, follow the guidelines in 
the Maintain Forced Air Cooling Note to Users included in the NI PXI-5114 kit. 
The NI PXI-5114 is intended for indoor use only.
Specification
Value
Comments
Operating 
Temperature
0 ºC to +55 ºC in all NI PXI chassis except the following:
0 ºC to +45 ºC when installed in an NI PXI-1000/B or 
PXI-101x chassis. 
Meets IEC-60068-2-1 and IEC-60068-2-2.
Storage 
Temperature
– 40 ºC to +71 ºC. Meets IEC-60068-2-1 and 
IEC-60068-2-2.
Operating Relative 
Humidity
10% to 90%, noncondensing. Meets IEC-60068-2-56.
Storage Relative 
Humidity
5% to 95%, noncondensing. Meets IEC-60068-2-56.
Operating Shock
30 g, half-sine, 11 ms pulse. Meets IEC-60068-2-27. Test 
profile developed in accordance with MIL-PRF-28800F.
Storage Shock
50 g, half-sine, 11 ms pulse. Meets IEC-60068-2-27. Test 
profile developed in accordance with MIL-PRF-28800F.
Operating Vibration
5 Hz to 500 Hz, 0.31 g
rms
. Meets IEC-60068-2-64.
Storage Vibration
5 Hz to 500 Hz, 2.46 g
rms
. Meets IEC-60068-2-64. 
Test profile exceeds requirements of MIL-PRF-28800F, 
Class B.
Altitude
2,000 m maximum (at 25 °C ambient temperature)
Pollution Degree
2