Cutout dimensions
Clearance dimensions
Electrical Requirements
Recommended Grounding Method
This compactor is for use on a single phase, 115-volt, 60 Hz, AC 
only 15 or 20 ampere fused and properly grounded circuit and is 
equipped with a grounding plug as shown below. Time delay fuse 
or circuit breaker is recommended. It is recommended that a 
separate circuit serving only this appliance be provided. In the 
event of an electrical short circuit, grounding reduces the risk of 
electric shock by providing an escape wire for the electric 
current. Do not modify the plug attached to the compactor; use 
only with a grounded receptacle.
This compactor must be grounded while in use to reduce the risk 
of electric shock. The compactor is equipped with a three-
conductor cord and three-prong grounding-type plug to fit the 
proper grounding-type receptacle. The green (or green and 
yellow) conductor in the cord is the grounding wire. Never 
connect the green (or green and yellow) wire to a live terminal. 
The outlet should be properly installed and grounded in 
accordance with the National Electrical Code and Local codes 
and ordinances. No adapter should be used with this appliance.
1. Grounded electrical outlet must be a minimum of 3 in. (7.6 cm) 
away from surrounding cabinets or nearby walls as shown. It can 
be placed either to the left or the right side of the product.
1. Leave 6 in. (15.2 cm) of clearance space to the right side of 
the compactor in order to remove the compactor bags. 
2. Leave 23 in. (58.4 cm) of clearance in front of the compactor 
in order to fully open or remove the compactor drawer.
18" min.
(45.7 cm)
24" min.
(61 cm)
1
15
min.
(38.7 cm)
34 " min.
(87 cm)
3"
(7.6 cm)
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Failure to follow these instructions can result in
death, fire, or electrical shock.
Do not use an adapter.
Do not remove ground prong.