Right (Decaf) Dispense Total
Reset Total to Zero (00.0 Gal)
 
LCD DISPLAY 
 PROGRAM MODE 
 DESCRIPTION
PROGRAMMING THE DISPENSER (Cont.)
Program Mode (Continued)
Empty Product Threshold
Set Conductance Threshold
Default = 600
Range = 100 Min / 900 Max
To check Conductance of Hot Water, 
view the display while rinsing. Set value 
to 100 above reading.
Displays Software Version # -
Exits To Home View After 3 Seconds.
Rinse Alarm Timer
Default = OFF > Rinse Alarm Disabled
Range = 1 - 24 hrs
Reminder Only. No Lock Out.
To clear alarm, set to RINSE Mode. 
Press Left switch, then Right switch 
for 15 seconds each.
38791 063009
MENU
(-)
(+)
P 7
0
0.
MENU
(-)
(+)
P 8 6 0 0
MENU
(-)
(+)
O
P 9
F F
MENU
(-)
(+)
LC x x
0
Program Lockout Function:
 The operator must hold down the stop and portion control button for 10 sec-
onds while machine is in program mode. At 10 seconds, the machine's display changes from "PPP" to "PP LOC" 
indicating the locked position. At this point, the operator may view the setup functions, but not alter any of the 
parameters. In order to unlock the machine, repeat the aforementioned process. A MemoryLocked flag is set in 
eeprom so that the machine will retain this setting if power is lost.
Function Lockout Feature
Prevents the user from changing set-up 
functions
 
LCD DISPLAY 
 PROGRAM FUNCTION 
 DESCRIPTION
MENU
(-)
(+)