3) Install a ground wire from the icemaker fan motor junction box to the remote condenser 
unit junction box. Use wire of an appropriate gage and outdoor rating. 
4) Install line and neutral wires from the fan motor leads in the icemaker fan motor junction 
box to the leads in the remote condenser unit junction box. Use wire of an appropriate 
gage and outdoor rating.
5) Replace the junction box covers and the louver panel in their correct positions.
7. Stacking Remote Condenser Unit
1) Install the lower remote condenser unit as described earlier in this section.
2) Place the upper remote condenser unit on top of the lower. See Fig. 16.
3) Secure the upper remote condenser unit to the lower remote condenser unit with the 
4 screws provided.
4) Install refrigerant lines and make electrical connection as described earlier in this 
section.
Fig. 16
Upper Remote
Condenser Unit 
Screws
Lower Remote
Condenser Unit 
Screws