TROUBLESHOOTING
10) If Tank Water Heater has trouble
Bad contact of connector/
insert correctly
1) Wire connector
2) Replace Heater
2) Replace Heater
Is MAIN PCB connector
(CN79) inserted correctly?
Is Tank Water Heater
normal?(about72ohm)
Is the input voltage of
IC01 MICOM #6 normal?)
Start
NO
YES
YES
YES
NO
1) Recheck the wire
2) Replace PCB MAIN
2) Replace PCB MAIN
NO
Normal(recheck)
Measure the resistance between
#6~#10 after CN79 connector
open 72ohm
± 7%
ERROR Code
☞ Checking method of Tank Water Heater
resistance CN79#6(Pink)
↔ #10(White)
**
∞Ω: Open(wire disconnection, heater
disconnection) trouble 0
Ω: Short trouble
☞ Checking method of Tank Water Heater
resistance CN78#5(Black)
↔ #4(Brown)
**
∞Ω: Open(wire disconnection, heater
disconnection) trouble 0
Ω: Short trouble
Start
YES
YES
YES
Initial
power On Heater off
Working
heater
3.5V~4.8V
MICOM
#6
3.5V~4.8V
0V
AW-SEM Transform(RF267,2#3957D8
2009.8.20 4:54 PM