Jenn-Air W10329370A Manual Do Utilizador

Página de 58
5
Connect to Refrigerator 
1. Create a service loop (minimum diameter of 2 ft [61 cm]) with 
the copper tubing. Avoid kinks when coiling the copper 
tubing. 
2. Remove the plastic cap from water valve inlet port. Place a 
compression nut and sleeve on the copper tubing. 
3. Insert the end of the copper tubing into the water valve inlet 
port. Shape tubing slightly so that the tubing feeds straight 
into the port to avoid kinks.
4. Slide the compression nut over the sleeve and screw into the 
water valve inlet port. 
5. Using an adjustable wrench, hold the nut on the plastic water 
line to keep it from moving. Then, with a second wrench turn 
the compression nut on the copper tubing counterclockwise 
to completely tighten. Do not overtighten.
6. Check connection by pulling on copper tubing. Attach copper 
tubing to refrigerator cabinet with a “P” clamp. Turn on water 
supply to refrigerator and check for leaks. Correct any leaks.
Complete the Installation
1. Plug into a grounded 3 prong outlet.
NOTE: Allow 24 hours to produce the first batch of ice. Discard 
the first three batches of ice produced. Allow 3 days to completely 
fill the ice container.
A. Plastic water tubing
B. Sleeve
C. Compression nut
D. Copper tubing
A. “P” clamp
B. Plastic water line
C. Compression nut
D. Copper tubing
B
A
C
D
B
C
D
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING