INSTALLATION 
 
 
 
that configuration  is the maximum the device will draw from V
BUS 
in either mode. 
The device  must  observe  this maximum,  regardless  of its mode.  If a configuration  supports  only  one power 
mode  and the power  source  of the device  changes,  the device  will lose its current  configuration  and address 
and return to the Powered state. If a device is self-powered  and its current configuration  requires  more than 
100 mA, then if the device switches to being bus-powered,  it must return to the Address state. Self-powered 
hubs that use V
BUS 
to power  the Hub Controller  are allowed  to remain  in the Configured  state if local power 
is lost. 
A hub port must be powered in order to detect port status changes, including  attach and detach. Bus powered 
hubs do not provide  any downstream  power  until they are configured,  at which point they will provide  power 
as  allowed  by  their  configuration  and  power  source.  A  USB  device  must  be  able  to  be  addressed  within  a 
specified  time  period  from  when  power  is  initially  applied.  After  an  attachment  to  a  port  has  been  detected, 
the host may enable the port, which will also reset the device attached to the port. 
 
 
6.3.6.1.3  
Default 
After the device  has been powered,  it must not respond  to any bus transactions  until it has received  a reset 
from the bus. After receiving  a reset, the device is then addressable  at the default address. 
When the reset process is complete,  the USB device is operating  at the correct speed (i.e., low-/full- 
/highspeed). 
The speed selection  for low- and full-speed  is determined  by  the device  termination  resistors.  A device  that is 
capable  of high-speed  operation  determines  whether  it will operate  at high-speed  as a part of the reset process 
A  device  capable  of  high-speed  operation  must  reset  successfully  at  full-speed  when  in  an  electrical 
environment  that is operating  at full-speed.  After the device is successfully  reset, the device must also 
respond  successfully  to device  and configuration  descriptor  requests  and return  appropriate  information. 
The device  may or may not be able to support its intended functionality  when operating at full-speed. 
 
 
6.3.6.1.4  
Address 
All USB devices  use the default  address  when initially  powered  or after the device  has been reset. Each USB 
device  is  assigned  a  unique  address  by  the  host  after  attachment  or  after  reset.  A  USB  device  maintains  its 
assigned address while suspended. 
A USB device responds to requests on its default pipe whether the device is currently  assigned a unique 
address or is using the default address. 
 
 
6.3.6.1.5  
Configured 
Before  a USB  device’s  function  may  be  used,  the  device  must  be  configured.  From  the  device’s  perspective, 
configuration  involves  correctly  processing  a SetConfiguration ()  request with a non-zero  configuration  value. 
Configuring  a  device  or  changing  an  alternate  setting  causes  all  of  the  status  and  configuration  values 
associated  with endpoints  in the affected interfaces to be set to their default values. 
This includes setting the data toggle of any endpoint using data toggles to the value DATA0. 
 
 
6.3.6.1.6  
Suspended 
In  order  to  conserve  power,  USB  devices  automatically  enter  the  Suspended  state  when  the  device  has 
observed  no bus traffic  for a specified  period.  When suspended,  the USB device  maintains  any internal  status, 
including  its address and configuration. 
All devices  must suspend  if bus activity  has not been  observed  for the length  of time.  Attached  devices  must 
be prepared  to suspend  at any time they are powered,  whether  they have been assigned  a non-default  address 
or are configured.  Bus  activity  may  cease  due  to the  host  entering  a suspend  mode  of its  own.  In addition,  a 
USB  device  shall  also  enter  the  Suspended  state  when  the  hub  port  it  is  attached  to  is  disabled.  This  is 
referred to as selective suspend. 
A USB device exits suspend mode when there is bus activity. A USB device may also request the host to exit 
suspend  mode  or selective  suspend  by using electrical  signaling  to indicate  remote  wakeup.  The ability  of a 
device  to  signal  remote  wakeup  is  optional.  If  a  USB  device  is  capable  of  remote  wakeup  signaling,  the 
device must support the ability of the host to enable and disable this capability.  When the device is reset,