OPERATION
ELECTRICAL CONNECTIONS
Install a separate 10VAC / 15AMP dedicated circuit with GFCI (Ground Fault Circuit Interrupter) protection. 
At initial start-up with power ON, push the GFCI test button. The reset button should pop out. Push this button in to reset. If the GFCI fails to 
operate in this manner, there is a ground fault or malfunction, indicating the possibility of electrical shock. 
Turn off the power and do not
use the bath until the source of the problem has been identified and corrected.
1. Route two separate branch circuits to the junction box near the whirlpool as shown in Figure . Each branch circuit MUST BE GFCI
    PROTECTED and must use copper conductors only.
. Ensure the heater and pump are properly GROUNDED and BONDED as required. Attach the AWG solid copper conductor supplied with
    the heater from the heater bonding lug to the motor frame bonding lug as shown in Figure 3. The conductor is secured to the lugs using set
    screws. The motor frame shall have a second AWG solid copper conductor connected from the frame bonding lug to the homes electrical
    panel or approved local bonding point as shown in Figure 3.
Fig. 2
Fig. 3
Fig. 1
WARNING: Prior to operation, review the Important Safety Instructions 
listed at the beginning of this instruction manual.
Once the heater is installed and the whirlpool pump is operating, the heater is 
totally automatic. The heater will help maintain the temperature of the water in 
the bath.
Pressure Switch
The heater is equipped with a preset pressure switch. The pump must be 
running with water flowing in the whirlpool to allow the heater to turn on.
Indicator Light
This light turns on whenever the heater is operating.
High-Limit Switch
The heater includes an exclusive "Intelligent High-Limit". This safety circuit will not "false trip" from hot tap water. It will only turn the heater 
off if the thermostat fails. If the high-limit trips frequently, call a service technician. 
To manually reset the circuit in the event that the “High-Limit” switch has been activated, simply (1) Turn off the whirlpool pump. () Drain 
water from the tub. (3) Remove power from heater by unplugging at receptacle or turning off circuit breaker. () The heater circuit will 
automatically reset in less than 15 minutes. (5) Restore power to the heater. () Whirlpool bath is now ready to use.
ELECTRICAL DIAGRAM
READ AND FOLLOW ALL INSTRUCTIONS
B
L
A
C
K
W
H
IT
E
120 VAC
GND.
SEPARATE 20 AMP GFCI OUTLET
for2.1 H.P. PUMP
SEPARATE 15 AMP GFCI OUTLET
for 1.6 H.P. PUMP
PUMP/MOTOR
ELECTRICAL INSTALLATION
HEATER
B
L
A
C
K
W
H
IT
E
120 VAC
GND.
SEPARATE
15 AMP GFCI OUTLET
HEATER “ON” LIGHT
Bonding Lug on
Heater Housing
E-Z INSTALL
WHIRLPOOL
HEATER
RUN AWG SOLID COPPER 
CONDUCTORS FROM 
HEATER BONDING LUG TO 
PUMP/MOTOR FRAME LUG 
AND FROM PUMP/MOTOR 
LUG TO APPROVED 
GROUND AS SHOWN
(PUMP/MOTOR)
TO GROUND
SECOND 
COPPER 
CONDUCTOR
FIRST COPPER 
CONDUCTOR
PUMP/MOTOR FRAME WITH 
BONDING LUGS
HEATER ON
E-Z INSTALL
WHIRLPOOL
HEATER
FACTORY INSTALLED - NOT FOR RESALE
HEATER P/N: 753174-100
(HEATER)