The control continuously monitors system parameters for control and oven failures and reports a fault code 
when a system problem is detected. The control utilizes the ovens blue “on light” and oven “heating light” to 
report a detected fault code. The control will continue to flash the lights in the appropriate sequence as long as 
the fault exists. 
 
Detection of a fault does not hinder the ability of the control to continue to function if the fault is not critical for 
the intended operation. For example: If the range door latch is inoperative, the range will continue to cook since 
the fault would only prevent the range from self-cleaning. 
 
ERROR CODE 
LIGHT SEQUENCE CODE 
             DESCRIPTION 
E1 22 
EEPROM 
ERROR 
E2 
01 
CONTROL NOT CALIBRATED 
E3 10 
SENSOR 
OPEN 
E4 12 
SENSOR 
SHORTED 
E5 21 
POTENTIONMETER 
FAILURE 
E6 32 
OVER 
TEMPERATURE-COOKING 
E7 23 
OVER 
TEMPERATURE-CLEANING 
E9 
43 
NO COOLING FANS 
E11 
44 
DOOR LATCH FAULT 
E12 
11 
EXP. BOARD NOT CONNECTED 
E13 
13 
VCC LIFT OFF ERROR 
E14 
55 
SELECTOR SWITCH ERROR