Smeg CP60X Manual Do Utilizador

Página de 21
Instructions for the Installer
64
15.2 Burner and nozzle characteristics table
Burner
Rated heating 
capacity
(kW)
LPG – G30/G31  28/37 mbar
Nozzle 
diameter
1/100 mm
By-pass
1/100
mm
Reduced 
flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliaire
1.0
50
30
350
73
71
Semi rapid
1.75
65
33
450
127
125
Triple crown
3.2
91
65
1500
233
229
Burner
Rated heating 
capacity
(kW)
NATURAL GAS – G20  20 mbar
Nozzle diameter
1/100 mm
Auxiliaire
1.0
72
350
Semi rapid
1.75
97
450
Triple crown
3.5
133
1500
15.3 Arrangement of the burners on the hob
BURNERS
1. Auxiliary
2. Semi rapid
4. Triple crown
ø min e max (in cm.)
12 - 14
16 - 24
18 - 26