Kenwood TK-7150 Manual Do Utilizador

Página de 58
TK-7150
44
CN201
CN202
VR700
VR1
L201
1
2
L205
L206
CV
L207
L208
L209
L210
1
2
TC501
TX
TC502
RX
CV
7. Adjustment Points
7-1. Component Side View
7-2. Foil Side View
VR1 : TX high power (High)
VR700 : MIC seisitivity
TC501 : PLL lock voltage (TX)
TC502 : PLL lock voltage (RX)
L201 : AF coil adjustment
L205,207,209 : MCF (Wide)
L206,208,210 : MCF (Narrow)
Item
Condition
Measurement
Adjustment
Specifications/
Remarks
Test-
equipment
Unit
Terminal
Parts
Unit
Method
ADJUSTMENT
21. Squelch
1) CH-SIG : 1-1
SSG
Rear
ANT
Front
Selector Adjust to point of
Set the value to 255.
open
Select Sql_O_ _ _ _
✽✽✽
panel
panel
knob
opening squelch
Adjust the SSG out-
• Wide
in tuning mode
put to “Condition”.
SSG output : Value when 3dB AF VTVM
EXT.SP
Then, decrease the
is subtracted from the
Distortion
value to the point of
sensitivity value of 12dB
meter
opening the squelch.
SINAD.
Oscilloscope
4Ω dummy
• Narrow
2) [PF5] key : Set the narrow
load
n_ _
Sql_O_ _ _ _
✽✽✽
in tuning mode
SSG output : Value when 4dB
is subtracted from the
sensitivity value of 12dB
SINAD.
• Wide/Narrow 3) SSG output : OFF
Check
Squelch must be
closed.
Note : When you change the Squelch adjustment value, connect all necessary measuring equipment (as stated in the adjustment procedure), then
adjust it to the SSG output value.