e-STUDIO3511/4511  FIRMWARE UPDATING
6 - 2
November 2003  ©  TOSHIBA TEC
6.1   Firmware Updating with Download Jig
In this equipment, it is feasible to update the firmware automatically by connecting the download jig
using the dedicated connector and turning ON the equipment.
The download jig consists of the ROM, in which the program is written, and the jig board. And three
types of the download jigs are available for each type of the firmware.
For updating the firmware, in addition to the current ways such as updating each firmware individually,
the batch update of the firmware of the equipment is available (except the hard disk and the option).
Firmware
Master data
System ROM
Engine ROM
Scanner ROM
NIC ROM
RADF ROM
Finisher ROM
(Finisher firmware)
Finisher ROM
(Saddle stitcher
firmware)
FAX ROM
Stored
Hard disk
System control PC board
(SYS board)
Logic PC board
(LGC board)
Scanning section control
PC board
(SLG board)
NIC board
RADF control PC board
(MR-3015)
Finisher control PC board
(MJ-1023/MJ-1024)
Finisher control PC board
(MJ-1024)
FAX board (GD-1150)
Individual update
PWA-DWNLD-350-JIG2
(48 MB)
PWA-DWNLD-350-JIG1
(16 MB)
K-PWA-DLM-320
or
PWA-DWNLD-350-JIG1
(16 MB)
K-PWA-DLM-320
or
PWA-DWNLD-350-JIG1
(16 MB)
PWA-DWNLD-350-JIG1
(16 MB)
K-PWA-DLM-320
K-PWA-DLM-320
K-PWA-DLM-320
K-PWA-DLM-320
Batch update
PWA-DWNLD-350-JIG1
(16 MB)
Download jig
Refer to the following for the details to update with each download jig.
6.1.1 PWA-DWNLD-350-JIG2 (48 MB)
6.1.2 PWA-DWNLD-350-JIG1 (16 MB)
6.1.4 K-PWA-DLM-320