Install and Cable the Cabinets 
Page 1-90
Install Emergency Transfer Unit and Associated Telephones 
1
NOTE:
Install the panel so it can be accessed only by authorized personnel. 
The location must meet standard environmental considerations such 
as temperature, humidity, and so forth.
2. Verify dial tone is present at each trunk circuit.
Figure 1-41.
808A Emergency Transfer Panel
3. Locate the circuit start selection switches. See 
Figure 1-41
. These are the 
first 10 two-position switches on the left side of the 808A. The switches set 
each of the 5 incoming trunk lines to either loop start or ground start. Two 
Figure Notes
1. 808A emergency transfer panel
2. Circuit start selection switches
3. Trunk identification label
4. 25-pair male connector