DELL 7.4 Manual Do Utilizador

Página de 232
Cause and 
Action
Cause: The only physical disk available to be assigned as a hot spare is using SAS 
technology. The physical disks in the virtual disk are using SATA technology. 
Because of this difference in technology, the hot spare cannot rebuild data if one 
of the physical disks in the virtual disk fails.
Action: Add a SATA disk that is large enough to be used as the hot spare and assign 
the new disk as a hot spare.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
Event ID — 2210
Description
Battery requires reconditioning. Initiate the battery learn cycle.
Severity
Warning / Non-critical
Cause and 
Action
Cause: Battery is in warn only mode and requires reconditioning.
Action: Initiate the battery learn cycle.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: None
SNMP Trap 
Numbers
1153
Event ID — 2211
Description
The physical disk is not supported.
Severity
Warning / Non-critical
Cause and 
Action
Cause: The physical disk may not have a supported version of the firmware or the 
disk may not be supported by your service provider.
Action: If the disk is supported, update the firmware to a supported version. If the 
disk is not supported by your service provider, replace the disk with one that is 
supported.
Related Alert 
Information
Clear Alert Number: None
Related Alert Number: None
Local Response Agent (LRA) Number: 2070
SNMP Trap 
Numbers
903
111