Recommended Usage
Planar UltraRes User Manual
13
Normal Use Thermal Guidelines
Normal use of the LCD module is defined as operating in the open air to prevent heat 
buildup, and without direct or indirect heat sources such as lighting fixtures, heating 
ducts, or direct sunlight that can cause the modules to experience high operating 
temperatures. If the LCD module will be installed in a recessed area with an LCD 
surround or enclosure, ensure adequate openings are applied for proper air flow and 
ventilation.
At 3000 meters or below, the maximum ambient operating temperature for the LCD 
module cannot be above 40º C nor below the minimum ambient operating 
temperature of 0º C. If one of these conditions exists, it is up to the installer to ensure 
that module placement is changed, thermal shielding is provided and/or additional 
ventilation is provided to keep the display within its nominal operating parameters.
Cooling Requirements
For optimal performance, active cooling by the installer should be planned for when 
the ambient temperature anywhere in the wall is predicted to be above the specified 
ambient temperature for the display.
Using the Display in Flat or Tilted Orientation
The Planar UltraRes is not recommended for use in flat orientation for tabletop, floor, 
or ceiling installations. LCD panels of this size are at risk of panel deflection, which 
can cause cosmetic sagging, brightness uniformity issues, a shortened life span, and 
malfunction of optional touch sensors. Installations where the display is tilted 
downward or upward at an angle may also be prone to these issues and are not 
recommended.