Installation / connection 
 
4.2 Connection 
M200D AS-Interface Basic 
Manual, 03/2009, A5E01668085-01 
63
 
Pin assignment   
The following diagrams show examples of circuits (2 and 3-wire system): 
 
2-wire system 
3-wire system 
 

 
 
 


 
 
 
 
 
Note 
The supply voltage for the digital inputs is short-circuit proof. The current is limited to max. 
200 mA. If a short-circuit or overload situation occurs in the sensor supply, the contact block 
(motor) and brake output are shut down and a group fault is output. You must acknowledge 
this fault with a trip reset. 
 
 
4.2.6.2 
Digital output 
The motor starter is equipped with a digital output, which you can connect directly to an 
actuator. The output is active when a group fault is present. 
The output can be loaded to max. 0.5 A and protected electronically against short-circuits. 
   
A connector (M12, 4 or 5 pin) is used for establishing the connection. The motor starter is 
equipped with a range of sockets. 
 
Example: Connecting the digital output