Desa H) AND VM42(B Manual Do Utilizador

Página de 28
108795-01M
For more information, visit www.desatech.com
16
P
IL
O
T
ON
OFF
IN
OUT
IN
Figure 39 - Control Knob in the PILOT position
Position Indicator
Gas Control Knob
TO TURN OFF GAS 
TO APPLIANCE
1.  Turn off the wall switch.
2.  Turn off all electric power to the appliance if service is to 
be performed.
3.  Fully open glass doors if installed.
4.  Remove front hearth brick and control access panel.
5.  Turn gas control knob clockwise 
 to “OFF”. Do not 
force.
6.  Replace front refractory brick access panel.
7.  Fully close glass doors if installed.
Figure 40 - Pilot
Thermopile
Pilot Burner
Ignitor
Pilot 
Adjustment 
Screw
OPERATING FIREPLACE
FOR YOUR SAFETY 
READ BEFORE LIGHTING
 WARNING: If you do not follow these instructions 
exactly, a fire or explosion may result causing property 
damage, personal injury or loss of life.
A.  This appliance has a pilot which must be lighted by hand. 
When lighting the pilot, follow these instructions exactly.
B.  BEFORE LIGHTING smell all around the appliance area 
for gas. Be sure to smell next to the floor because some gas 
is heavier than air and will settle on the floor.
 
WHAT TO DO IF YOU SMELL GAS
•  Do not try to light any appliance.
•  Do not touch any electric switch; do not use any phone 
in your building.
•  Immediately call your gas supplier from a neighborʼs 
phone. Follow the gas supplierʼs instructions.
•  If you cannot reach your gas supplier, call the fire de-
partment.
C.  Use only your hand to push in or turn the gas control knob. 
Never use tools. If the knob will not push in or turn by hand, 
donʼt try to repair it, call a qualified service technician or 
gas supplier. Force or attempted repair may result in a fire 
or explosion.
D.  Do not use this appliance if any part has been under water. 
Immediately call a qualified service technician to inspect 
the appliance and to replace any part of the control system 
and any gas control which has been under water.
LIGHTING 
INSTRUCTIONS
NOTICE: During initial operation of new heater, burning 
logs will give off a paper-burning smell. Orange flame 
will also be present. Open damper or window to vent 
smell. This will only last a few hours.
1.  STOP! Read the safety information, above.
2.  Turn wall switch to the OFF position.
3.  Turn off all electric power to the appliance.
4.  Fully open glass doors if installed.
5.  Remove front refractory brick access panel.
6.  Turn gas control knob clockwise 
 to the OFF position 
(see Figure 39).
7.  Wait five (5) minutes to clear out any gas. Then smell for gas, 
including near the floor. If you smell gas, STOP! Follow “B” 
in the safety information above. If you donʼt smell gas, go to 
the next step.
8.  Turn control knob counterclockwise 
 to the PILOT 
position.
9.  Push in the knob all the way and hold in. Immediately light 
the pilot manually. Continue to hold the control knob in for 
about (1) minute after the pilot is lit. Release knob and it will 
pop back up. Pilot should remain lit. If it goes out, repeat 
steps 5 through 9.
•  If knob does not pop up when released, stop and imme-
diately call your service technician or gas supplier.
•  If the pilot will not stay lit after several tries, turn the gas 
control knob to “OFF” and call your service technician 
or gas supplier.
10.  Turn gas control knob counterclockwise 
 to “ON”. 
Knob can be turned to “ON” only if the control knob is 
popped out.
11.  Replace front refractory brick access panel.
12.  Fully close glass doors if installed.
13.  Turn on all electric power to the appliance.