DIMENSIONS
HEARTH AREA
7"
Figure 1 - Appliance Dimensions
PRODUCT SPECIFICATIONS
GAS RATING - NATURAL
M36(B,H), VM36(B,H) M42(B,H), VM42(B,H)
Max. Input Rating:
40,000 Btu/Hr
45,000 Btu/Hr
Manifold Pressure:
3.5 in. WC (.87 kPa)
3.5 in. WC (.87 kPa)
Minimum Supply Pressure: 4.5 in. WC (1.12 kPa) 4.5 in. WC (1.12 kPa)
Maximum Supply Pressure: 10.5 in. WC (2.66 kPa) 10.5 in. WC (2.66 kPa)
Orifice Size:
Maximum Supply Pressure: 10.5 in. WC (2.66 kPa) 10.5 in. WC (2.66 kPa)
Orifice Size:
# 30
# 29
GAS RATING - PROPANE/LP
M36P(B,H), VM36P(B,H) M42P(B,H), VM42P(B,H)
Max. Input Rating:
40,000 Btu/Hr
45,000 Btu/Hr
Manifold Pressure:
10 in. WC (2.49 kPa) 10 in. WC (2.49 kPa)
Minimum Supply Pressure: 11 in. WC (2.74 kPa) 11 in. WC (2.74 kPa)
Maximum Supply Pressure: 13 in. WC (3.23 kPa) 13 in. WC (3.23 kPa)
Orifice Size:
Maximum Supply Pressure: 13 in. WC (3.23 kPa) 13 in. WC (3.23 kPa)
Orifice Size:
# 52
# 50
CAUTION: Do not connect appliance before pressure
testing gas piping. Damage to gas valve may result and
an unsafe condition may be caused.
The appliance and itʼs individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of
that system at test pressures in excess of 1/2 psig (3.5 kPa).
The appliance must be isolated from the gas supply piping system
The appliance must be isolated from the gas supply piping system
by closing its individual manual shutoff valve during any pressure
testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).
For the purpose of input adjustment two pressure taps (for IN and
For the purpose of input adjustment two pressure taps (for IN and
OUT
pressures) are provided on the gas control valve for test gauge
connections to the appliance.
INTRODUCTION
Continued
Model 36
Model 42
Model 36 Model 42
Model 36 Model 42
A 29"
36"
I
40
1
/
4
"
44
1
/
4
"
Q 13
7
/
8
"
14"
B 5/8"
5/8"
J 21"
24"
R 10
1
/
2
"
12
1
/
2
"
C 41"
48"
K 8"
9"
S 2
1
/
2
"
2
1
/
2
"
D 12"
14"
L 34
3
/
4
"
42"
T 8
1
/
8
"
8
1
/
8
"
E 21
1
/
4
"
23"
M 42"
49"
U 11"
12
3
/
4
"
F 22
1
/
4
" (24" w/o Brick)
29
1
/
4
" (31" w/o Brick)
N 36"
40"
V 7"
7"
G 32
5
/
8
" (34" w/o Brick)
39
1
/
2
" (41
1
/
4
" w/o Brick) O 37"
41"
W 2
1
/
4
"
2
1
/
4
"
H 15
3
/
4
" (16
3
/
4
" w/o Brick) 17
3
/
4
" (18
3
/
4
" w/o Brick) P 8
5
/
8
"
10
1
/
2
"
X 5"
4
1
/
2
"