INSTALLATION
IMPORTANT MESSAGE
The Regency Gas Inbuilt must be installed in 
accordance with these instructions. Carefully 
read all the instructions in this manual fi rst.  
Note:  Failure to follow these instructions 
could cause a malfunction of the 
heater which could result in death, 
serious bodily injury, and/or prop-
erty damage.  Failure to follow these 
instructions may also void your fi re 
insurance and/or warranty.  
FOR YOUR SAFETY
This appliance requires air for proper combus-
tion.  Always provide adequate combustion 
and ventilation air. Follow instructions and 
information in the current AS5601, NZS 5262 
or local codes.  Consult the "authority having 
jurisdiction" to determine the need for a permit 
prior to starting the installation.
BEFORE YOU START
Installation is to be carried out ONLY by an 
authorised person.
1)  The appliance shall be  installed in accord-
ance with the manufacturer's installation 
instructions, local gas fi tting  regulations, 
municipal building codes, water supply 
regulations, electrical wiring regulations, 
with AS5601. (AGA gas installation code) 
NZS 5262(New Zealand)
2)  Installation and repair should be done 
ONLY by an authorised person.  
3)  The  appliance should be inspected before 
use and at least annually by an authorised 
service person. More frequent cleaning may 
be required due to excessive lint from carpet-
ing, bedding material, etc.  It is imperative 
that control compartments, burners and 
circulating air passageways of the appliance 
be kept clean and free from excessive lint 
from carpeting.
4)  See general construction and assembly 
instructions. This appliance may only be in-
stalled in a fl ued, non-combustible fi replace. 
The appliance and fl ue should be enclosed 
when installed or passing through a living 
area, where children may come in contact 
with it.
5)  Always connect this space heater to a chim-
ney and fl ue to the outside of the building 
envelope. Never fl ue to another room.  Make 
sure that the fl ue is properly sized and is 
of adequate height to provide the proper 
draft.  
6) Inspect the fl ueing system annually for 
blockage and any signs of deterioration.   
7)  Any safety glass removed for servicing 
must be replaced prior to operating the ap-
pliance.  
8)  To prevent  injury, do not allow anyone who 
is unfamiliar with the operation to use the 
fi replace.
9)  Installer must mechanically attach the sup-
plied label to the inside of the fi rebox of the 
fi replace into which the gas fi replace insert 
is installed.  
MATERIALS REQUIRED
A 240 Volt AC power cord is hooked up to the 
unit. Plug 3 wire cord into a suitable receptacle. 
Do not cut the ground terminal off under any 
circumstances.
When connected with 240 volts, the appliance 
must be electrically grounded in accordance 
with local codes.
This unit is polarity sensitive and will not 
operate if polarity is incorrect.
"WARNING: This fi replace has been converted 
for use with a gas fi replace insert only and 
cannot be used for burning wood or solid fuels 
unless all original parts have been replaced, 
and the fi replace re-approved by the authority 
having jurisdiction."
WARNING
Suitable for installation into a masonry 
fi replace only.
INSTALLATION 
CHECKLIST
Before installing vent system ensure that the 
damper plate is open and secure to prevent the 
damper plate from falling down and crushing 
the liner.
The FPI Gas Inbuilt is installed as listed.
1)  Check all clearances to combustibles, (Refer 
to sections "Minimum Fireplace Dimensions 
and Clearances to Combustibles)
2)  Make the gas connection. (Refer to section 
"Gas Connection")
3)  Install the 3" (76.2mm) fl ue liner to the sliding 
connector plate. (Refer to section "Flue Liner 
Installation.")
4)  Slide the unit half way into the fi replace.
5)  Pull the vent connector plate through the 
tapered brackets and fasten to the front plate. 
Refer to section "Flue Liner Installation.")
6)  Slide the unit fully into the fi replace. 
7)  Test gas pressure (Refer to section "Gas 
Pipe Pressure Testing"). Check aeration 
system (Refer to section "Gas Insert Aeration 
System").
8)  Install standard and optional features.  Refer 
to the following sections: 
 
a. Log Set 
 
b. Faceplate & Door Trim
      c.  Inner Stainless Panels 
9)  Final check: Before leaving this unit with the 
customer, the installer must ensure that the 
appliance is fi ring correctly. This includes:
 
a)  Clocking the appliance  to ensure the 
correct fi ring rate.
 
b)  Adjusting the primary air and restrictor 
settings, if required, to ensure that the 
fl ame does not carbon.
NOTE:   
TO BE INSTALLED ON A 
 NON- COMBUSTIBLE FLOOR.