9. ROUTINE MAINTENANCE and SERVICE 
Periodically check to ensure that your system is clean. 
 
Periodically check the pilot and burner.  Check to see that 
all the burner ports are clean and clear.  Check the pilot 
head for blockage.  Check to ensure the pilot flame is blue 
with yellow tips. 
 
NOTE: Wipe the gold louvers with a soft cloth 
before firing unit.  If left, fingerprints can become 
etched in the gold.  
OPENING THE DOOR 
 
Turn unit off and wait until the appliance has cooled down. 
 
Open the lower louver panel.  Undo the two bolts at the 
bottom corners of the door.  Swing door out, then lift up 
and out to remove. 
 
Ensure the door is properly fastened after cleaning before 
attempting to re-light the appliance. 
 
CLEANING THE GLASS 
 
Do not clean glass when hot
 
 
It will be necessary to clean the ceramic glass periodically.  
During a cold start up, condensation will sometimes form 
on the glass, this is a normal condition with all gas 
fireplaces and stoves.  However, this condensation can 
allow dust and lint to cling to the glass surface. Initial paint 
curing of the appliance can leave behind a slight film on 
the glass.  This is a temporary problem. It is therefore 
recommended that the glass be cleaned initially after 
about the first two weeks of use. 
 
To clean the door use a mild glass cleaner and a soft 
cloth.
  Abrasive cleaners will damage the glass and 
gold surfaces. 
 
TO REPLACE DOOR GLASS  
 
The glass in this appliance is 5 MM ceramic.  If the glass is 
damaged or broken a factory replacement must be fitted. 
To Replace: 
• 
Open door, remove the glass carefully. 
• 
Install the new piece of glass with the large bulb in the 
gasket tape against the unit.  Place the joint in the 
tape in a bottom corner.  Close door 
Glass must be purchased from an Envirogas dealer.   
No substitute materials are allowed. 
 
CLEANING THE INSIDE OF THE FIREBOX 
 
Remove the log carefully from the firebox.  Gently remove 
the embers and place on a piece of paper towel.  Until 
ready to replace. 
 
Vacuum the bottom of the firebox thoroughly.  Carefully 
clean off any dust on the logs and brick panels and 
remove any lint from the main burner and pilot burner. 
 
After carefully replacing the log and embers in their correct 
positions, and the door has been resealed, re-light the 
pilot, following the instructions on the attached label. 
 
CLEARANCES MUST BE SUFFICIENT TO ALLOW 
ACCESS FOR MAINTENANCE AND SERVICE 
 
Depending upon the amount of use, cleaning should be 
required no more than two or three times per season. 
 
REMOVING BURNER CONTROLS: 
 
1.   Shut of gas supply to appliance. 
 
2.  Remove surround panels by pulling up then out.  
disconnect gas line from the valve.  Disconnect 
harness at connector on side of unit. 
 
3.  Open the door and remove the log.  Remove the 
burner tray assembly by removing the two screws on 
either side of the tray.  Pull tray up at the back, lift tray 
out and towards the front. 
 
4.  Remove the brick panel as per instructions.  Undo the 
three screws that hold the burner control tray onto the 
back firewall.  Lift control tray up on the left side and 
pull out.  Remove wire connector from firebox. 
 
5.  Installation is the reverse  
 
Caution:  
Bleed lines before lighting and light 
pilot with door open 
 
ADJUSTING VENTURI AIR SETTINGS 
 
There is one venture and one air shutter on this 
appliance. 
The venture has been set for installations at sea level. 
Some adjustment could be required. 
 
• 
To adjust for high altitude: open the lower louvers, 
locate the venturis between the burner and control 
trays. Loosen the set screws with a long screwdriver 
and rotate the air shutter until an efficient flame is 
achieved. 
 
 
12