Enviro 25BV Manual Do Utilizador

Página de 19
TABLE OF CONTENTS 
 
SECTION  
PAGE 
1. Code 
Approvals 
2.  Dimensions and Clearances to Combustibles 
3. Venting 
4.  Assembly and Installation Instructions 
5. Electrical 
Requirements 
6.  Gas Line Connection and Testing 
7.  Installation of Log Sets and Embers and Brick Panels 
10 
8. Operating 
Instructions 
11 
9.  Routine Maintenance and Service 
12 
10.  Fuel Conversion  
13 
11. Trouble 
Shooting 
14 
12.  Parts and Accessories 
15 
13. Warranty 
16 
14.  Installation Data Sheet 
17 
 
1. CODES AND APPROVALS 
 
VENTED type is identified by the suffix BV
.  This appliance draws in room air for combustion and vent dilution 
air. 
• 
These appliances have been tested by Intertek Testing Services. and found to comply with the established standards for 
GAS FIRED VENTED ROOM HEATER in CANADA and the USA as follows:- 
 
LISTED VENTED ROOM HEATER (EG 25 BV Nat. & LPG ) 
TESTED TO:  ANSI Z21.88-1998       CSA 2.33.M98 VENTED GAS FIREPLACE HEATER 
 
CANADA and U.S.A. 
 
CERTIFIED FOR INSTALLATION FROM 0 - 2000 FT (810 M) 
FOR INSTALLATIONS ABOVE 2000 FEET (810 m) 
•  In Canada the unit must be derated by 10% for installation at elevations between 2,000 (810 m)and 4,500 
feet (1370 m). 
NATURAL 
GAS 
         PROPANE 
GAS 
INPUT: 20814 (6.09 Kw)   #44 DMS  
 
 
 
INPUT: 22257 (6.52 Kw)   #54 DMS 
 
 
 
 
• 
In the USA, these appliance are certified for elevations up to 2,000 feet (810 m).  For elevations above 2,000 
feet (810 m), input should be reduced 4% for each 1,000 feet (405 m) above sea level.
 
 
ACCENT 25
 
•  Has been certified for use with either natural or propane gases. (see rating label.) 
•  Is not for use with solid fuels. 
•  Is approved for bedroom or bedsitting room. (A thermostat must be installed in Canada.) 
•  Must be installed in accordance with local codes. 
If none exist use current installation code CAN/CGA  B149 in Canada or ANSI Z223.1/NFPA 54 in the USA. 
• 
Must be properly connected to a venting system
  
 
WARNING: For installation only in a solid fuel burning fireplace with a working flue and 
constructed of non-combustible material using a chimney liner kit.
 
3