FOR INSTALLATIONS ABOVE 2000 FEET 
 
•  In Canada, these appliances are certified for altitudes of 0-2,000 feet and must be derated by 10% for 
installation at elevations between 2,000 and 4,500 feet.   
•  In the USA, these appliance are certified for elevations up to 2,000 feet.  For elevations above 2,000 feet, 
input should be reduced 4% for each 1,000 feet above sea level. 
 
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous 
operating conditions and was determined independently of any installed system.
 
3. DIMENSIONS AND CLEARANCES TO COMBUSTIBLES
 
 
FIREPLACE INSERT CLEARANCES TO COMBUSTIBLES:
 
 
A. Mantle pillar to stove 
   10" / 
25 cm 
B. Stove top to 8" wide mantle  12" / 31 
cm 
 Stove must sit on a non-combustible 
surface, the width and depth of the 
insert 
 Maintain sufficient clearances 
for operation, service and maintenance  
OTHER DIMENSIONS 
A. Depth of unit into fireplace      11¼" /  
28.5 cm 
B. Depth of unit out of fireplace  8 ¾” /  22.2 cm 
C. Minimum firebox size  W 26" x H 20” x D 20" 
 
 
 
 (W 66 x H 50 x D 50 cm) 
 
  Figure 
1
 
 
 
 
 
 
 
 
 
 
FREESTANDING CLEARANCES TO COMBUSTIBLES:
 
 
 
A. Side wall to stove   
10" 
B. Rear wall to stove    
  4" 
C. Combustible to stove Top  22" 
D. Floor to stove 
 
  0" 
E. Corner clearance 
 
  2" 
F. Alcove depth 
 
48" 
Maintain sufficient clearances 
for service and maintenance  
 
 
 
 
 
 
 
 
 
 
 
 
Figure 2
 
 