Charmglow 720-0230 Manual Do Utilizador

Página de 33
 
 
GAS HOOK-UP 
 
Only the pressure regulator and hose assembly supplied 
with the grill should be used. Any replacement pressure 
regulator and hose assembly must be specified by the 
grill manufacturer. 
 
This is a propane configured grill. Do not attempt to 
use a natural gas supply unless the grill has been 
reconfigured for natural gas use. 
 
Total gas consumption (per hour) of the 720-0230 
(Charmglow) Grill with all burners on “HI”: 
 
Main burners 
 
36,000 Btu/hr. 
Side burner 
 
12,000 Btu/hr. 
Total 
  48,000 
Btu/hr.
 
 
The installation of this appliance must conform with 
local codes or, in the absence of local codes, with the 
national fuel gas code, ANSI Z223. 1a-1988. 
Installation in Canada must be in accordance with 
the Standard Can1-b149.1 and/or .2 (installation code 
for gas burning appliances and equipment) and local 
codes. 
 
L.P. Tank Requirements 
A dented or rusty L.P. tank may be hazardous and 
should be checked by your L.P. supplier. Never use a 
cylinder with a damaged valve. The L.P. gas cylinder 
must be constructed and marked in accordance with 
the specifications for L.P. gas cylinders of the U.S. 
Department of Transportation (DOT), or the 
National Standard of Canada, CAN/CSA-B339, 
Cylinders, Spheres and Tubes for Transportation of 
Dangerous Goods; and Commission. 
 
The cylinder must be provided with a shut valve 
terminating in an L.P. gas supply cylinder valve 
outlet specified, as applicable, for connection type 
QCC1 in the standard for compressed gas cylinder 
valve outlet and inlet connection ANSI/CGA-V-1. 
 
The cylinder supply system must be arranged for 
vapor withdrawal. The cylinder must include a collar 
to protect the cylinder valve. 
 
Manifold pressure: (operating): 10” water column 
(W.C.), (non-operating): 11.2” water column (W.C.). 
 
L.P. GAS HOOK-UP: 
Ensure that the black plastic grommets on the LP 
cylinder valve are in place and that the hose does not 
come into contact with the grease tray or the grill 
head. 
 
CONNECTION: 
Your 720-0230 (Charmglow) grill is equipped with 
gas supply orifices for use only with propane gas. It is 
also equipped with a high capacity hose/regulator 
assembly for connection to a standard 20lb. L.P. 
cylinder (18-1/4” high, 12-1/4” diameter). 
 
To connect the L.P. gas supply cylinder, please follow 
the steps below: 
1.  Make sure tank valve is in its full off position 
(turn clockwise to stop) 
2.  Check tank valve to assure it has proper external 
male threads (type 1 connection per ANSIZ21.81) 
3.  Make sure all burner valves are in their off 
position. 
4. Inspect 
valve 
connections, port, and regulator 
assembly. Look for any damage or debris. 
Remove any debris. Inspect hose for damage. 
Never attempt to use damaged or obstructed 
equipment. See your local L.P. gas dealer for 
repair. 
5.  When connecting regulator assembly to the valve, 
hand tighten the nut clockwise to a complete stop. 
Do not use a wrench to tighten. Use of a wrench 
may damage the quick coupling nut and result in 
a hazardous condition. 
6.  Open the tank valve fully (counterclockwise). Use 
a soapy water solution to check all connections 
for leaks before attempting to light the grill, see 
below. If a leak is found, turn the tank valve off 
and do not use the grill until a local L.P. gas 
dealer can make repairs. 
 
To disconnect L.P. gas cylinder: 
1.  Turn the burner valves off. 
2.  Turn the tank valve off fully (turn clockwise to 
stop). 
3. 
Detach the regulator assembly from the tank 
valve by turning the quick coupling nut 
counterclockwise.
 
LEAK TESTING 
 
GENERAL 
Although all gas connections on the grill are leak tested 
at the factory prior to shipment, a complete gas tightness 
check must be performed at the installation site due to 
possible mishandling in shipment, or excessive pressure 
unknowingly being applied to the unit. Periodically 
check the whole system for leaks following the 
procedures listed below. If the smell of gas is detected at 
anytime you should immediately check the entire system 
for leaks. 
 16