Aussie 6122S8X641 Manual Do Utilizador

Página de 40
23
LP Hose and Regulator
To reduce the risk of serious bodily injury or death 
from fire or explosion:
• Clean and inspect the gas hose/regulator before 
each use of the outdoor cooking gas appliance. 
The gas hose/regulator must be replaced prior to 
being used, if there is evidence of excessive abra-
sion or wear, or if the hose is cut or leaks. 
• Use only the gas hose/regulator assembly that 
has been supplied with this gas grill. Do not 
use hose/regulator from another manufacturer. 
Replacement gas hose/regulator assembly must be 
specified by this grill’s manufactuer before using.
• Always check for gas leaks when you connect 
and disconnect the hose/regulator to the LP Gas 
Cylinder, especially after a period of storage (for 
example, over winter).
• Make sure there are no sharp bends in the hose.
• Make sure the hose/regulator does not contact any 
heated surfaces.
WARNING
!
NOTE: 
If the hose/regulator assembly is not working properly 
and you need a replacement, contact Customer Service 
at 1-800-251-7558
 or go to www.aussiegrills.com.
Be sure to have the grill model number and serial 
number
 printed on the black label, located inside the 
left door of the cabinet. If you need a replacement 
part under warranty, a proof of purchase will be 
necessary. You will be asked to forward your proof of 
purchase via e-mail or to fax your proof of purchase 
to 423-639-1055 and reference your model and serial 
number. It is important to register your grill and 
retain your receipt.
Connecting LP Gas Cylinder
Fill empty OPD LP Gas Cylinder at your local gas supplier. 
1. Place the LP Gas Cylinder on the Cylinder Support with the nozzle opening facing outward (to left). Make sure the 
bottom ring on the cylinder sits in the notches in the Cylinder Support. This helps prevent cylinder movement.
2. Lift the Cylinder Retainer Wire and tilt the cylinder so the collar is under the center of the wire. Lower the wire onto 
the collar as shown with the center loop inside the cylinder collar. The fit will be snug to hold the cylinder in place.
3. Remove the protective cap from the LP Gas Cylinder valve. (Save cap for re-capping.)                                         
Hold Regulator in a straight line with LP Gas Cylinder valve so the connection does not cross thread.                  
Insert Regulator Nipple into the LP Gas Cylinder valve. Hand tighten coupling nut in clockwise direction.           
DO NOT USE TOOLS.
Disconnecting LP Gas Cylinder
1. Turn all Control Knobs to the “Off” position and turn the handle on the LP Gas Cylinder clockwise until it stops.
2. Turn coupling nut counterclockwise until regulator is released from the threaded LP Gas Cylinder nozzle.
3. Place the protective cap over LP Gas Cylinder nozzle.
Hand-tighten coupling 
nut in clockwise direction
To reduce the risk of serious bodily injury or death 
from fire or explosion:
• Be sure to route the regulator hose, from the side 
burner valve to the tank, UNDER THE LEG BRACE, 
as shown below.
WARNING
!
1
2
3