7) Make sure at least 10 minutes have elapsed since you poured the cleaning solution 
over the extruding head, then move the control switch to the "ICE" position.
8) Allow the appliance to make ice for 20 minutes, then move the control switch to the 
"DRAIN" position.
9) Allow the water system to drain for 1 minute.
10) Move the control switch to the "ICE" position.
11) After the gear motor starts, move the control switch to the "DRAIN" position.
12) Allow the water system to drain for 1 minute.
13) Move the control switch to the "OFF" position. In severe water conditions, repeat the 
cleaning procedure.
Note: If you do not sanitize the appliance, go to step 8 in "IV.B.5. Sanitizing 
Procedure - Final."
3. Sanitizing Solution
Dilute 1.25 fl. oz. (37 ml or 2.5 tbs) of a 5.25% sodium hypochlorite solution (chlorine 
bleach) with 2.5 gallons (9.5 l) of warm water. This is a minimum amount. Make more 
solution if necessary. Using a chlorine test strip or other method, confirm that you have a 
concentration of about 200 ppm. 
IMPORTANT! For safety and maximum effectiveness, 
use the solution immediately after dilution.
4. Sanitizing Procedure - Initial
1) Using a clean funnel and hose, pour 1 qt (1 l) of sanitizing solution over the extruding 
head. Allow the appliance to sit for 10 minutes before operation.
2) Remove the slope from the storage bin by carefully bending it in the center and 
releasing it from the 2 slope shafts.
3) Remove the scoop. Remove the 2 thumbscrews securing the scoop holder, then remove 
it.
4) Pour some of the sanitizing solution into a separate, clean container. Using this 
sanitizing solution and a clean cloth, wipe down the slope, scoop, scoop holder, inside 
of the spout, and bin liner.
5) Rinse the parts and areas sanitized in step 4 thoroughly with clean water.
6) Replace all removed parts in their original and correct positions. 
WARNING! CHOKING 
HAZARD: Ensure all components, fasteners, and thumbscrews are securely in 
place. Make sure that none have fallen into the storage bin.
7) Make sure at least 10 minutes have elapsed since you poured the sanitizing solution 
over the extruding head, then move the control switch to the "ICE" position.
8) Allow the appliance to make ice for 20 minutes, then move the control switch to the 
"DRAIN" position.
9) Allow the water system to drain for 1 minute.
10) Move the control switch to the "ICE" position.
11) After the gear motor starts, move the control switch to the "DRAIN" position.
12) Allow the water system to drain for 1 minute.
13) Move the control switch to the "OFF" position.