Yamaha LIT-11626-16-27 Manual Do Utilizador

Página de 132
6 - 8
+
ELEC
CARBURETOR HEATING SYSTEM
Å The thermo switch circuit is open.
ı The thermo switch circuit is closed.
Test step Water temperature Continuity
1
Less than 23 
± 3 ˚C
(73.4 
± 5.4 ˚F)
YES
2
More than 23 
± 3 ˚C
(73.4 
± 5.4 ˚F)
NO
3
More than 12 
± 4 ˚C
(53.6 
± 7.2 ˚F)
NO
4
Less than 12 
± 4 ˚C
(53.6 
± 7.2 ˚F)
YES
Test steps 1 & 2: Heating phase
Test steps 3 & 4: Cooling phase
WARNING
Handle the thermo switch with special
care.
Never subject the thermo switch to
strong shocks. If the thermo switch is
dropped, replace it.
Check the thermo switch operation.
CARBURETOR HEATER INSPECTION
1. Inspect:
Carburetor heater resistance
Out of specification 
→ Replace.
Tester (+) probe 
 
Carburetor heater terminal 1
Tester (–) probe 
Carburetor heater body 2
Carburetor 
heater resistance
Tester selector 
position
6 ~ 10 
Ω at 
20 ˚C (68 ˚F)
Ω × 1