10.6.  SETTING LIMIT ALARMS 
 
 
 
 
   From 
 
 
 
 
SETUP/CAL 
 
 
 
Menu 
 
 
 
 
 
 
 
10.6.1.  Setting a Single Channel’s High Limit 
After selecting a channel in the SETUP/CAL menu, choose ALARMS by pressing the number 5 key 
followed by the ENTER key.  The ALARMS menu will be displayed.  Pressing the number “1” key 
selects the HIGH LIMIT display.  Using the number keys, enter the desired high limit level and then 
press ENTER.  EXIT the loop by pressing the number “4” + ENTER  key while the ALARMS menu is 
displayed. 
10.6.2.  Setting a Single Channel’s Low Limit 
After selecting a channel in the SETUP/CAL menu, choose ALARMS by pressing the number 5 key.  
The ALARMS menu will be displayed.  Pressing the number 2 key selects the LOW LIMIT display.  
Using the number keys, enter the desired high limit level and then press ENTER.  EXIT the loop by 
pressing the number 4 key while the ALARMS menu is displayed, followed by ENTER
10.6.3.  Setting a Single Channel’s Hysteresis 
After selecting a channel in the SETUP/CAL menu, choose ALARMS by pressing the number 5 key.  The 
ALARMS menu will be displayed.  Pressing the number 3 key selects the HYSTERESIS display.  Using 
the number keys, enter the desired degree of Hysteresis followed by the ENTER key.  EXIT the loop by 
pressing the number 4 key while the ALARMS menu is displayed, followed by ENTER. 
 
 
Each channel of the POWER
POD
-
400 has one high limit alarm and 
one low limit alarm.  Each alarm is 
provided by an open-collector, 
opto-isolated signal at a 
corresponding pin on the rear 
panel, connector J8.  Use the 
provided diagram when referring 
to the text below.