Mitsubishi Electronics Q170MCPU Manual Do Utilizador

Página de 274
 
 
 
6 - 9 
6   INSPECTION AND MAINTENANCE 
 
6.5.2 Battery replacement procedure 
When the battery has been exhausted, replace the battery with a new one in 
accordance with the procedure shown below. 
 
POINTS 
 
When replacing the battery, pay attention to the following. 
(1)   Back up the data using MT Developer2 before starting replacement. 
 
(2)   Firstly back up the data stored in the Motion controller to the personal 
computer which is installed MT Developer2 then replace the battery with a new 
one. After setting the battery in the Battery holder, verify the backing up the 
data to the personal computer which is installed MT Developer2 and the data 
in the Motion controller, confirm the data is not changing. 
In the following status, the backup time after power OFF is 3 minutes. 
• The lead connector of Q6BAT/Q7BAT is disconnected. 
• The lead wire of Q6BAT/Q7BAT is broken.