ADC Dual Inline Tower Mounted Amplifier System Manual Do Utilizador

Página de 28
ADCP-75-214 • Issue 2 • September 2006
Page 20
© 2006, ADC Telecommunications, Inc.
5.3
PDU (Power Distribution Unit)
 provides typical specifications for the PDU.
Table 4. Power Distribution Unit (PDU) Specifications
CATEGORY
PARAMETER
SPECIFICATION
Electrical
Input voltage range
20–56VDC positive/negative ground 
(Input polarization protected)
Output voltage
15V, 4% (Over voltage protection)
Output voltage accuracy
4% in 20mA – 400mAMAX 10% in 1.5A
Output ripple
100mV pk – pk
PDU Inrush Current
ETS300132-2, Part 2
Short circuit protection
1500mA, 10%
Connector and 
LED
Outputs for TMA's
SMB connector Male (3 pcs)
Input connector
Molex Micro-fit 43045 - 0400
General alarm connector
Molex Mini-Fit 39-30-3035
Communications link between BTS 
and RET
Molex Mini-Fit 39-30-3035
Indicators
Two color LED (3 pcs) (green and yellow) 
Red LED 1 pcs
Physical
Dimensions (W x H x D)
194.4 x 43.6 x 100.0 mm
(7.7 x 1.7 x 3.9 inches)
Weight
0.5 Kg (1.2 lbs.)
Color
Gray Metallic
Communication
Pin Number
Signal
Comments
1
RS485 A
RET control command AISG Layer2. ISO/
IEC 8482:1993 (RS485).
2
RS485  B
3
RS485 GND
PDU only receives control command from BTS and modulates 2.176MHz Modem 
Signal and transmit to TMA through SMB connector, and vice versa.
Resistance between RS485 A and 
RS485 B
> 1k Ohm
Resistance between RS485 A or 
RS485 B and DC return / RS485 GND
> 1k Ohm
Capacitance between RS485 A or 
RS485 B
< 1nF
Capacitance between RS485 A or 
RS485 B and DC/RS485 GND
< 1nF