NetAXS™ Access Control Unit User’s GuideDocument 800-04410, Revision A
65
3
Configuring via WIN-PAK
In this chapter...
3.1  Overview
This chapter explains the NetAXS™ configuration functions as accessed via the 
Quick Start Wizard (QSW) in WIN-PAK 2005, WIN-PAK PRO 2005, WIN-PAK SE, 
and WIN-PAK PE. The QSW creates the ADV options and adds the panel to the 
Control Map and the Master Access Level.
These functions should be performed only by the NetAXS™ system administrator or 
service personnel.
Notes:
• WIN-PAK 2.0, release 4, uses the same steps provided in this chapter to 
configure NetAXS™; however, its screens are not exactly the same.
• NetAXS™ cannot be added to WIN-PAK PRO Release 4 or older.
• For a new Site installation, or for adding to an existing Site, follow the 
procedures in this chapter as you would when you add an N-1000-IV-X panel. 
One exception to this is that the NetAXS™ panel does not support the use of 
the C-100-A1 (20ma current loop installations). Therefore, when you select 
the Loop type, 485 ACK<-NAK is the only supported type. Direct is reserved 
for NS2P; C-100 is not supported.
• If the NetAXS™ panel is configured as a Gateway panel, it appears to 
WIN-PAK as an N-485-PCI or N-485-HUB. Using the NetAXS™ panel as a 
Gateway, you should not add N-1000/PW-2000 panels as a downstream panel 
to the NetAXS™ gateway. The NetAXS™ gateway is designed for more 
efficient downstream communications than what can be supported by the 
N-1000/PW2000 panels.