Mitsubishi Electronics AJ65BT-D75P2-S3 Manual Do Utilizador
10 - 19
MELSEC-A
10 ADVANCED POSITIONING CONTROL
10.4.2 Condition data setting examples
The following shows setting examples for "condition data".
(1) Setting the device ON/OFF as a condition
[Condition] Device "RXn0" (=D75P2 READY) is ON
Da.14
Condition
target
Da.15
Condition
operator
Da.16
Address
Da.17
Parameter 1
Da.18
Parameter 2
01
H
: Device X
07
H
: DEV=ON
–
0
–
(2) Setting the numeric value stored in the "buffer memory" as a
condition
[Condition]
The value stored in buffer memory addresses "802, 803" (=" Md.30 Machine
feed value") is "1000" or larger.
feed value") is "1000" or larger.
Da.14 Condition
target
Da.15
Condition
operator
Da.16
Address
Da.17
Parameter 1
Da.18
Parameter 2
04
H
: Buffer memory
(2 words)
03
H
:
P1
802 1000 –
(3) Designating the axis and positioning data No. to be
simultaneously started in "simultaneous start"
[Condition]
Simultaneously starting "axis 2 positioning data No.3".
Da.14 Condition
target
Da.15
Condition
operator
Da.16
Address
Da.17
Parameter 1
Da.18
Parameter 2
05
H
: Positioning
data No.
0A
H
: Axis 2
designation
–
High-order 16
bits "0003
H
"
*1
–
*1: For the starting axis (axis where positioning start takes place), set the
value to "0000
H
".