Renesas SH7264 Manual Do Utilizador
![Renesas](https://files.manualsbrain.com/attachments/59153266feca598c11e08bf1f143ccfcf45441a4/common/fit/150/50/d3d06de51d338eb4f916b44a9629f9d48697a59cd7344be40cf24bae01c5/brand_logo.gif)
Section 11 Multi-Function Timer Pulse Unit 2
R01UH0134EJ0400 Rev. 4.00
Page 493 of 2108
Sep 24, 2014
SH7262 Group, SH7264 Group
Table 11.32 TIOC4B Output Level Select Function
Bit 4
Function
OLS3P Initial Output
Active Level
Compare Match Output
Up Count
Down Count
0
High level
Low level
Low level
High level
1
Low level
High level
High level
Low level
Table 11.33 TIOC4C Output Level Select Function
Bit 3
Function
OLS2N Initial Output
Active Level
Compare Match Output
Up Count
Down Count
0
High level
Low level
High level
Low level
1
Low level
High level
Low level
High level
Note: The reverse phase waveform initial output value changes to the active level after elapse of
the dead time after count start.
Table 11.34 TIOC4A Output Level Select Function
Bit 2
Function
OLS2P Initial Output
Active Level
Compare Match Output
Up Count
Down Count
0
High level
Low level
Low level
High level
1
Low level
High level
High level
Low level
Table 11.35 TIOC3D Output Level Select Function
Bit 1
Function
OLS1N Initial Output
Active Level
Compare Match Output
Up Count
Down Count
0
High level
Low level
High level
Low level
1
Low level
High level
Low level
High level
Note: The reverse phase waveform initial output value changes to the active level after elapse of
the dead time after count start.