Xantrex Technology 300 Manual Do Utilizador

Página de 61
Troubleshooting Reference
37
AC appliance 
will not 
operate; 
audible alarm 
is sounding.
Battery has discharged to 
10.5 V.
XPower Powerpack has 
overheated due to poor 
ventilation or excessively 
warm environmental 
conditions.
Turn 
OFF
 the AC Power 
ON
/
OFF
 
switch and recharge the XPower 
Powerpack.
Turn the AC Power 
ON
/
OFF
 
switch 
OFF
 and allow the 
XPower Powerpack to cool for 
15 minutes or more. Clear 
blocked opening or remove 
objects covering the unit, then 
restart the XPower Powerpack 
and move it to a cooler 
environment.
Run time is 
less than 
expected.
XPower Powerpack 
battery is not fully 
charged.
AC appliance power 
consumption is higher 
than expected.
Environmental 
temperature is less than 
0°C (32°F) or more than 
40°C (104°F)
Recharge using the AC charger, 
until Battery Status LED is 
green.
Check AC appliance power or 
wattage rating (or current draw 
for 12 V DC appliances) and 
compare with Table 3-1 on 
page 14 and T
able 3-2 on 
page 17.
Operate within correct 
temperature range.
Table 5-1 Troubleshooting reference
Problem
Possible Cause
Solution