Section 21   IEBus
TM
 Controller 
R01UH0134EJ0400  Rev. 4.00  
 
Page 1093 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(a)  Master Transmission 
The master unit transmits the data bits and parity bit to the slave unit to write data from the master 
unit to the slave unit. The slave unit receives the data bits and parity bit, and returns an 
acknowledgement if the parity bit is even and the receive buffer is empty. If the parity bit is odd or 
the receive buffer is not empty, the slave unit does not accept the corresponding data and does not 
return an acknowledgement. 
When the slave unit does not return an acknowledgement, the master unit retransmits the data. 
This operation is repeated until either an acknowledgement from the slave unit is detected or the 
maximum number of data transfer bytes is reached. 
When the parity is even and the acknowledgement is output from the slave unit, the master unit 
transmits the subsequent data if data remains and the maximum number of transfer bytes is not 
exceeded. 
In the case of broadcast communications, the slave unit does not return the acknowledgement, and 
the master unit transfers data byte by byte. 
(b)  Master Reception 
The master unit outputs synchronous signals corresponding to all data bits to be read from the 
slave unit. 
The slave unit outputs the data bits and parity bit on the bus in accordance with the synchronous 
signals from the master unit. 
The master unit reads the parity bit output from the slave unit, and checks the parity. If the parity 
is not even, or the receive buffer is not empty, the master unit rejects acceptance of the data, and 
does not return the acknowledgement. The master unit reads the same data repeatedly if the 
number of data does not exceed the maximum number of transfer bytes in one frame. If the parity 
is even and the receive buffer is empty, the master unit accepts data and returns an 
acknowledgement. The master unit reads in the subsequent data if the number of data does not 
exceed the maximum number of transfer bytes in one frame.