Renesas R5S72622 Manual Do Utilizador

Página de 2152
 
Section 28   Sampling Rate Converter 
Page 1654 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Bit Bit 
Name 
Initial 
Value R/W Description 
FLF 
Flush Processing Status Flag 
Indicates whether flush processing is in progress or 
not. 
[Clearing conditions] 
  When flush processing has been completed. 
  When 1 has been written to the CL bit in 
SRCCTRL. 
  When 1 has been written to the SRCEN bit in 
SRCCTRL while SRCEN is 0. 
[Setting condition] 
  When 1 has been written to the FL bit in 
SRCCTRL. 
3 UDF 0 R/(W)*
1
Output FIFO Underflow Interrupt Request Flag 
Indicates that the output data FIFO is read when the 
number of data units in the output data FIFO is zero. 
[Clearing conditions] 
  When 0 has been written to the UDF bit after 
reading UVF = 1. 
  When 1 has been written to the CL bit in 
SRCCTRL. 
  When 1 has been written to the SRCEN bit in 
SRCCTRL while SRCEN is 0. 
[Setting condition] 
  When the output data FIFO is read while the 
number of data units in the output FIFO is zero.