Renesas R5S72622 Manual Do Utilizador

Página de 2152
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 447 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
Table 11.10  Setting of Operation Mode by Bits MD0 to MD3 
Bit 3 
MD3 
Bit 2 
MD2 
Bit 1 
MD1 
Bit 0 
MD0 
 
Description 
0 0 0 0 Normal 
operation 
   1 
Setting 
prohibited 
  1 
PWM 
mode 
   1 
PWM 
mode 
2*
1
 
  1 0 0 Phase 
counting 
mode 
1*
2
 
   1 
Phase 
counting 
mode 
2*
2
 
 
 
Phase counting mode 3*
2
 
   1 
Phase 
counting 
mode 
4*
2
 
1 0 0 0 Reset 
synchronous 
PWM 
mode*
3
 
   1 
Setting 
prohibited 
  1 
Setting 
prohibited 
  1 0 0 Setting 
prohibited 
 
 
 
Complementary PWM mode 1 (transmit at crest)*
3
 
 
 
Complementary PWM mode 2 (transmit at trough)*
3
 
 
 
 
Complementary PWM mode 2 (transmit at crest and 
trough)*
3
 
[Legend] 
X: Don't 
care 
Notes:  1.  PWM mode 2 cannot be set for channels 3 and 4. 
 
2.  Phase counting mode cannot be set for channels 0, 3, and 4. 
 
3.  Reset synchronous PWM mode, complementary PWM mode can only be set for 
channel 3. When channel 3 is set to reset synchronous PWM mode or complementary 
PWM mode, the channel 4 settings become ineffective and automatically conform to the 
channel 3 settings. However, do not set channel 4 to reset synchronous PWM mode or 
complementary PWM mode. Reset synchronous PWM mode and complementary PWM 
mode cannot be set for channels 0, 1, and 2.