Section 11   Multi-Function Timer Pulse Unit 2 
 
R01UH0134EJ0400  Rev. 4.00  
 
Page 597 of 2108 
Sep 24, 2014 
 
 
 
SH7262 Group, SH7264 Group 
(4)  Status Flag Clearing Timing 
After a status flag is read as 1 by the CPU, it is cleared by writing 0 to it. When the direct memory 
access controller is activated, the flag is cleared automatically. Figure 11.96 shows the timing for 
status flag clearing by the CPU, and Figure 11.97 shows the timing for status flag clearing by the 
direct memory access controller. 
Status flag
Write signal
Address
TSR address
Interrupt
request signal
TSR write cycle
T1
T2
P
φ
 
Figure 11.96   Timing for Status Flag Clearing by CPU 
Interrupt
request signal
Flag clear
signal
Status flag
Address
Source address
Direct memory 
access controller
read cycle
Destination
address
Direct memory 
access controller
write cycle
P
φ, Bφ
 
Figure 11.97   Timing for Status Flag Clearing by Direct Memory Access Controller 
Activation