Renesas R5S72621 Manual Do Utilizador

Página de 2152
 
Section 21   IEBus
TM
 Controller 
Page 1130 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Bit Bit 
Name 
Initial 
Value R/W 
Description 
0 RXEPE 
R/(W)* Parity 
Error 
Indicates that a parity error has occurred during data 
field reception. If a parity error occurs before data field 
reception, this module immediately enters the wait state 
and the RXEPE flag is not set. 
If a parity error occurs when the maximum number of 
receive bytes in one frame have not been received, the 
RXEPE flag is not set yet. When a parity error occurs, 
this module returns a NAK to the communications 
destination unit via the acknowledge bit. In this case, 
the communications destination unit continues 
retransfer up to the maximum number of receive bytes 
in one frame and if the reception has been completed 
normally by clearing the parity error, the RXEPE flag is 
not set. If the parity error is not cleared when the 
reception is terminated before receiving data for the 
number of bytes specified by the message length, the 
RXEPE flag is set. 
In broadcast reception, if a parity error occurs during 
data field reception, this module enters the wait state 
immediately after setting the RXEPE flag. This flag is 
enabled only after the receive start flag (RXS) is set. If 
this error occurs before the receive start flag is set, this 
module stops communication and enters the wait state. 
This bit is not set in this case. 
[Setting condition] 
  When the parity bit of the last data of the data field 
is not correct after the maximum number of receive 
bytes have been received 
[Clearing condition] 
  When 1 is written 
Note:  *  only 1 can be written to clear the flag.