Renesas R5S72621 Manual Do Utilizador

Página de 2152
 
 
Section 11   Multi-Function Timer Pulse Unit 2 
 
Page 450 of 2108 
 
R01UH0134EJ0400  Rev. 4.00 
 
 Sep 
24, 
2014 
SH7262 Group, SH7264 Group
Table 11.11  TIORH_0 (Channel 0) 
    
Description 
Bit 7 
IOB3 
Bit 6 
IOB2 
Bit 5 
IOB1 
Bit 4 
IOB0 
TGRB_0 
Function 
 
TIOC0B Pin Function 
0 0 0 0 Output 
compare 
register 
Output retained* 
Initial output is 0 
0 output at compare match 
Initial output is 0 
1 output at compare match 
Initial output is 0 
Toggle output at compare match 
1 0 0 
Output 
retained 
 
Initial output is 1 
0 output at compare match 
Initial output is 1 
1 output at compare match 
Initial output is 1 
Toggle output at compare match 
1 0 0 0 Input 
capture 
register 
Input capture at rising edge 
Input capture at falling edge 
Input capture at both edges 
 
 
Capture input source is channel 1/count clock 
Input capture at TCNT_1 count-up/count-down 
[Legend] 
X: Don't 
care 
Note:  *  After power-on reset, 0 is output until TIOR is set.